Product Specification

  • Capacity: 2 kg to 5 kg
  • Fire Class: Class A, B, and C
  • Operating Temperature: -30°C to +60°C
Enquire Now

    Enquire About This Product

    Product Description:

    A non magnetic fire extinguisher for MRI room can be made of non-ferrous metal like aluminum and/or some special alloy to avoid danger under strong magnetic force. Besides, this type of MR-compatible equipment will use environmentally friendly gases like CO2 or de-ionized water because they are non-conductive and safe for sophisticated medical electronic equipment.

    Additional Details:

    • Brand: Somya Pyrotek Services Pvt. Ltd.
    • Model: Non Magnetic Fire Extinguisher For MRI Room
    • Capacity: 2 kg to 6 kg (or 5 lb to 13 lb)
    • Maximum Coverage Area: 2m to 23m
    • Temperature Range: -30°C to +60°C
    • Working Pressure: 50 to 60 bar
    • Rechargeability: Refillable
    • Cylinder Material: Non-magnetic austenitic stainless steel or lightweight aluminum alloys
    • Agent Release Time: 10 to 18 seconds

    Key Features of Non Magnetic Fire Extinguisher For MRI Room

    Here are the key features that every individual should look for when purchasing a non magnetic fire extinguisher for MRI room:

    • Extinguishers must be independently third-party labeled and tested for safety surveillance for safety in high magnetic fields. Non magnetic fire extinguisher guarantees the cylinder poses no projectile hazard.
    • Agents are particularly chosen not to conduct electricity, securing the operator from electrical shock and preventing short circuits in the MRI scanner’s sensitive electronic controls.
    • It eliminates the requirement for expensive clean-up and secures delicate electrical elements from corrosive chemical damage.
    • Designed to be easily pulled by medical staff who might be wearing protective equipment or dealing with an emergency.
    • The non magnetic fire extinguisher agents are non-toxic, pose no respiratory threats to patients or staff in confined imaging suites, and have zero ozone depletion potential.

    Applicable Areas of Non Magnetic Fire Extinguisher For MRI Room

    • Zone IV (Scanner Rooms)
    • Technologist Control Rooms
    • Equipment Rooms
    • Patient Holding/Recovery Bays
    • Radiofrequency (RF) Shielded Rooms
    • Cryogen Service Areas
    • Injector Setup Rooms
    • Nuclear Magnetic Resonance (NMR) Labs
    • Imaging Center Emergency Exits
    • Interventional MRI (iMRI) Suites

    Technical Configurations of Non Magnetic Fire Extinguisher For MRI Room

    Parameter Technical Specification
    Application Area MRI rooms, imaging suites, radiology departments, high magnetic field zones
    MRI Compatibility Certified MRI Safe or MRI Conditional
    Suitable MRI Field Strength Up to 3 Tesla (3T) or 7 Tesla (7T), depending on model
    Extinguisher Type Clean Agent / CO₂ / Water Mist (MRI-compatible models)
    Cylinder Material Aluminum alloy or composite non‑ferrous material
    Magnetic Properties Completely non‑magnetic construction
    Valve Assembly Brass, aluminum, or non‑ferrous alloy
    Hose & Horn Material Non‑magnetic rubber, polymer, or reinforced composite
    Extinguishing Agent Clean agent (FK‑5‑1‑12, FE‑36), Water Mist, or MRI-compatible CO₂
    Capacity Options 2 kg, 4.5 kg, 6 kg, 9 L, or customized capacities
    Operating Pressure Typically 12–18 bar, depending on extinguisher type
    Test Pressure Approximately 25–35 bar
    Temperature Range −20°C to +60°C (varies by agent type)
    Discharge Time 8–20 seconds, depending on capacity
    Discharge Range 2–6 meters
    Mounting Type Wall-mounted with non‑magnetic brackets
    Safety Pin Material Non‑ferrous metal or polymer-coated
    Gauge Type Non‑magnetic pressure gauge
    Corrosion Resistance Epoxy powder-coated or anodized finish
    Compliance Standards NFPA, CE, EN3, ISO, UL, FDA/MRI facility requirements
    MRI Safety Labeling Clearly marked “MRI Safe” or “MRI Conditional.”
    Color Coding Red body with MRI safety identification labels
    Maintenance Requirement Periodic hydrostatic testing and annual inspection
    Inspection Frequency Monthly visual inspection, annual servicing recommended
    Installation Zone Inside the MRI control room or a designated MRI safe area
    Recommended Fire Classes Class A, B, and C electrical fires, depending on the agent
    Typical Weight 3–14 kg, depending on capacity and construction
    Mobility Portable handheld unit
    Shelf Life 5–15 years, depending on the extinguisher agent
    Accessories Non‑magnetic wall brackets, inspection tags, protective covers

    Pros and Cons of Non Magnetic Fire Extinguisher For MRI Room

    Non magnetic fire extinguisher for MRI room is mandatory for safe operation inside magnetic resonance imaging (MRI) suites. Furthermore, let’s discuss some pros and cons before you buy the MRI room:

    Pros Cons
    Zero Projectile Hazard Limited Agent Versatility
    Protect Sensitive Equipment Oxygen Depletion Risks
    Code Compliance High Purchase Costs
    Safety from Electrical Shock Strict Tesla Rating Limits
    Clean Suppression Thermal and Electrical Hazards
    Improved Patient Transport Refill/Service Limitations
    Dedicated First Responder Support Accidental Exposure

    Safety Tips for Non Magnetic Fire Extinguisher For MRI Room

    Ensure to keep the below safety tips in mind for a non magnetic fire extinguisher for MRI room:

    • Even if the extinguisher is not magnetic, it has to be certified by a third party as MR-Conditional for your particular magnetic field strength of the scanner, either 1.5T, 3T, or 7T.
    • Choose extinguishing agents that are electrically insulating and leave as little residual as possible for delicate electronic equipment. Opt for a non-magnetic CO₂, Water Mist or Clean Agent extinguisher, and Water Mist is especially recommended because of its cooling effects with no thermal shock and oxygen depletion.
    • Since there is a constant and permanent magnetic field generated by the scanner, it would be safer to keep the MRI compatible extinguishers right outside the main door of the magnet room in the control area.
    • Do not let any firefighters or unauthorized persons enter the room using normal metallic extinguishers; all individuals should pass through a screening process for ferromagnetic metals prior to accessing the controlled environment.
    • Before trying to extinguish the fire inside the MRI scanner room, make sure to turn off all power sources of the MRI unit through emergency stop buttons marked with proper labels.

    Maintenance and Inspection Tips for Non Magnetic Fire Extinguisher For MRI Room

    Accurate maintenance and inspection ensure the fire extinguisher is always ready to operate safely. Moreover, here are some maintenance and inspection tips that you should consider to enhance the life span of the extinguisher:

    • Make sure the extinguisher has an appropriate non-ferrous/non-magnetic marking, such as aluminum/stainless steel extinguishers only. Regular red fire extinguishers are not allowed in the magnet room.
    • Look at the right place where the extinguisher is located. It should be visible and free of any obstruction. Operating instructions must face outward and be readable.
    • Check the extinguisher’s gauge to make sure that the needle stays in the green zone. Also, make sure the gauge window is clean and not damaged.
    • Make sure that the locking pin is placed in its position, and there is a tamper-proof plastic seal on the extinguisher. It indicates that it was not accidentally discharged or partially discharged.
    • Check the discharge hose and the nozzle regularly to prevent dust and blockage of the hose.

    Why Choose us When Buying Non Magnetic Fire Extinguisher For MRI Room?

    We manufacture a high-quality non magnetic fire extinguisher for MRI room that is highly recommended for MRI room use. Our products have been proven reliable in providing the best fire safety in MRI rooms and many other settings, such as hospitals, diagnostic centers, and imaging centers. With extensive experience in manufacturing fire extinguishers, we ensure our clients receive the ideal fire safety products for MRI rooms. Our products will enable our clients to enjoy prompt services due to quick installation and effectiveness.

    • Fire safety equipment for MRI rooms made from high-quality non-magnetic material
    • Guidance in choosing and installing fire protection equipment for MRI rooms
    • Dependable fire safety products quickly delivered across India
    • Effective and affordable fire safety solutions for all your needs
    • Fire protection products ideal for MRI rooms, health care facilities, laboratories, and business premises

    If you are searching for the right product, contact our team today to get genuine, certified products!

    Frequently Asked Questions

    Magnetic Resonance Imaging machines produce very strong magnetic fields, making regular fire extinguishers potentially dangerous as projectile weapons. A non Magnetic fire extinguisher has been specifically designed to ensure safe and reliable operation within MRI environments.

    Here are some advantages of non magnetic fire extinguisher:

    • Ensures no risk of becoming a projectile object near the MRI
    • Does not pose any danger to medical devices and equipment
    • Leaves no or very small amount of residues after being discharged
    • Easy to use, even for non-experienced medical personnel
    • Complies with all MRI Safety regulations
    • Can be used within hospitals, imaging centers, and laboratories

    This kind of extinguisher is widely used within MRI Scanner rooms, Control Rooms, Radiology Departments, RF Shielded Rooms, and Recovery Rooms. Can be used within NMR laboratories and Interventional MRI Rooms.

    Here are some steps you should take when choosing the right non magnetic fire extinguisher:

    • Should be certified as MRI Safe or MRI Conditional
    • Should correspond to your MRI scanner’s Tesla rating
    • Should be based on a clean agent or CO₂
    • The body and all its elements must be non-magnetic
    • Must comply with fire safety regulations;

    Not really, as most non-magnetic fire extinguishers use either clean agent or water mist that leaves no harmful residues behind, which helps reduce equipment damage and expenses on post-fire maintenance.

    Here are some maintenance tips that you must consider:

    • Ensure that the pressure indicator is checked regularly
    • Ensure the safety pin and tamper seal are still intact
    • Keep the extinguisher visible and easily accessible
    • Clean and check the hose and nozzle from time to time
    • Perform annual service and inspection