ABC Fire Extinguisher
Capacity: 1kg, 2kg, 4kg, 6kg, 9kg
Product Specification
- Capacity: 1 kg, 2 kg, 4 kg, 6 kg, 9 kg
- Fire Class: Class A (Solids), Class B (Liquids), Class C (Gases & Electrical)
- Extinguishing Medium: Dry Nitrogen or Clean Dry Air
- Operating Temperature: -20°C to +55°C
Product Description
An ABC fire extinguisher is a versatile and portable fire extinguishing tool designed to manage three common types of fires: Class A, Class B, and Class C. Furthermore, these fire extinguishers utilize monoammonium phosphate and dry chemical agents to stop and immediately extinguish fires. However, this particular substance works by strangling flames and disrupting the chemical reactions that fuel the fire.
Moreover, this portable fire extinguisher is lightweight and easy to handle, making it ideal for use in offices, industrial spaces, and homes. Their portable and handy design allows consumers to respond immediately to emergencies, preventing fires from escalating. Due to their extensive reliability and widespread application, they are one of the most popular fire extinguishers available in the Indian Market.
Application Area of the ABC Fire Extinguisher
- Residential Homes
- Offices
- Schools and Educational Institutions
- Hospitals and Clinics
- Hotels and Hospitality Sector
- Warehouses and Storage Facilities
- Retail Stores and Shopping Malls
- Factories and Manufacturing Plants
- Laboratories
- Fuel Stations and Petrol Pumps
- Vehicles (Cars, Buses, Trucks)
- Airports and Aviation Facilities
- Railway Stations and Coaches
- Banks and Financial Institutions
- Server Rooms and Data Centers
- Restaurants and Commercial Kitchens
- Temples and Religious Places
- Shopping Complexes and Multiplexes
- Construction Sites
- Government Offices and Public Buildings
Key Features of the ABC Fire Extinguisher
- The ABC fire extinguisher consists of multi-class firefighting capabilities.
- It provides a user-friendly operation.
- It offers monoammonium phosphate agents.
- It is non-conductive and safe.
- It is made up of a corrosion-resistant body.
- It has a pressure gauge indicator, which allows quick check ups.
- The ABC portable fire extinguisher has a long shelf life.
- It offers a wide temperature range.
- It is ISI and BIS Certified.
- It comes in a wide variety of sizes.
Technical Specifications of ABC Fire Extinguisher
Specification | Details |
---|---|
Type | ABC Dry Powder (MAP – Mono Ammonium Phosphate) |
Class of Fire | Class A (Solids), Class B (Liquids), Class C (Gases & Electrical) |
Available Capacities | 1 kg, 2 kg, 4 kg, 6 kg, 9 kg |
Fire Rating | Varies by size (e.g., 13A:89B for 6kg) |
Operating Temperature | -20°C to +55°C |
Discharge Time | 8–20 seconds (depending on capacity) |
Working Pressure | 15 bar (approx.) |
Burst Pressure | 35–55 bar (as per cylinder capacity) |
Propellant | Dry Nitrogen or Clean Dry Air |
Discharge Mechanism | Squeeze the lever with the safety pin and seal |
Body Material | Mild Steel, corrosion-resistant painted/coated |
Extinguishing Agent Content | 90% or higher MAP (depending on model) |
Testing Pressure | 30 bar |
Mounting Type | Wall-mounted with a bracket |
Standards Compliance | ISI Marked (IS: 15683), BIS Certified |
What are the Benefits Of an ABC Fire Extinguisher?
If you are looking for the effective advantages of an ABC fire extinguisher, check out the pointers we have mentioned below to gain detailed information.
- Compared to specialized extinguishers, they can be applied to a greater variety of fire types.
- Compared to other extinguisher types, such as foam or clean agent extinguishers, it is typically less expensive.
- The barrier formed by the dry powder aids in preventing radiant heat.
- It can put out fires caused by flammable liquids, wood, paper, cloth, and electrical equipment that has been energized.
- It works well in a range of temperatures.
What are the Disadvantages Of an ABC Fire Extinguisher?
After going through the imperative advantages, ensure to check out some crucial disadvantages of an ABC portal fire extinguisher:
- The powder may harm delicate electronics and can be challenging to clean up.
- A cloud formed by the powder may impair vision and possibly lead to respiratory issues.
- Ineffective on fires caused by cooking oil or grease.
- Particularly on electrical equipment, dry powder can react with water and cause corrosion.
- Computers, servers, and other sensitive electronics may sustain damage or a short circuit as a result of the residue.
How to Use an ABC Fire Extinguisher?
When using the ABC fire extinguisher, it is essential to remain stable, as the process is straightforward. However, here are some crucial steps to follow when using the fire extinguisher.
Step: 1 Pull the pin to unlock the fire extinguisher. Therefore, it will allow you to discharge it directly to the application areas or surfaces.
Step: 2 Ensure the nozzle is aimed at the base of the fire. Furthermore, concentrate on the source, not the flames.
Step: 3 Gently, squeeze the handle evenly and slowly to release the fire extinguishing agent.
Step: 4 Clean the nozzle from every corner at the base of the fire until it is entirely extinguished.
Hence, these simple steps are practical for most ABC portable fire extinguisher users. Additionally, you always ensure that you maintain complete control and remain stable during the process of extinguishing.
Maintenance and Inspection Tips of an ABC Fire Extinguisher
Here are maintenance and inspection tips that every individual should keep in mind to improve the shelf life of the ABC Fire Extinguisher:
- Inspect whether the extinguisher is conveniently accessible and not obstructed by items.
- Check that the pressure gauge needle is within the green range.
- Inspect for damage, corrosion, or leaks.
- Check that the nozzle or hose is not cracked or clogged.
- Check that the safety pin is intact and secured firmly by the tamper seal.
- If the seal is lost or broken, investigate and replace it immediately.
- Ensure the inspection tag is renewed after every monthly and yearly inspection.
- Mark the date and the inspector’s initials for accountability and tracking purposes.
- The pressure gauge must be within operable range (green zone).
- If high or low, the extinguisher is not likely to work effectively and requires service.
- Arrange for a complete inspection by a licensed fire safety professional annually.
- This involves inspecting the internal status, weight, discharge mechanism, and refilling when necessary.
- For dry-powder types, shake or turn the extinguisher every month to keep the powder loose.
- This ensures that the fire-extinguishing material remains loose and ready to discharge accurately.
- Inspect the cylinder for signs of rust, dents, or chemical leaks.
- Any outward damage must be reported and resolved immediately. Therefore, damage models must be replaced at times.
- Wipe clean with a soft, wet cloth to eliminate dust, dirt, or any grease accumulation.
- It is simpler to locate and utilize when it is clean in case of emergencies.
- Most ABC extinguishers last between 5 and 15 years, depending on the manufacturer.
- Replace the extinguisher once it reaches the manufacturer’s life cycle end-time.