Portable CO2 Fire Extinguisher

Portable CO2 Fire Extinguishers

CO2 Fire Extinguisher

Product Specification

  • Capacity: 2 Kg, 5 Kg
  • Fire Class: Class A, Class B, Class C (editable)
  • Extinguishing Media: Dry Powder IS 4308 (editable)
  • Operating Temperature: -20°C to +55°C (editable)
Enquire Now

    Enquire About This Product

    Product Description:

    The Carbon Dioxide (CO2) fire extinguisher is a specialized, high-pressure safety device designed primarily for Class B (flammable liquid) and electrical fires. Furthermore, it is an imperative, non-toxic, non-conductive agent that leaves no residue, making it well-suited for protecting breakable electronic equipment, server rooms, and laboratories.

    Furthermore, it works by displacing oxygen, suffocating the fire, while delivering a cooling effect. Likewise, the unit features a different black, hard horn (no pressure gauge) for direct application. Thus, manufacturer of CO2 type fire extinguishers ensures that they are available in portable 2kg to 5 kg or trolley-mounted sizes. Additionally, it is designed with red steel or aluminium cylinders that are essential for clean, rapid, and safe fire suppression.

    Additional Details:

    • Brand: Somya Pyrotek Services Pvt. Ltd.
    • Model: CO2 Fire Extinguisher
    • Capacity (CO2 Charge): 2 kg, 4.5 kg, 6.8 kg, 9 kg (common sizes)
    • Discharge Range:5 to 4 meters
    • Operating Temperature Range: -20°C to +60°C (standard)
    • Working Pressure: 55 bar (at 20°C)
    • Discharge Time: 8–25 seconds
    • Valve Type: Brass Alloy valve with safety burst disc
    • Total Weight (Filled): 6–16 kg (depends on capacity)

    Key Features of CO2 Fire Extinguisher

    Check out the fundamental features of a CO2 fire extinguisher designed by leading fire extinguisher manufacturers that you must know before purchasing it to safeguard your space:

    1. The CO2 fire extinguisher manufacturer ensures it is safe to use on live electrical tools, as it does not conduct electricity back to the user.
    2. Leaves no powder residue or oil, preventing damage to sensitive computer, laboratory machinery, or electronics.
    3. A manufacturer of CO2 type fire extinguishers ensures that it is ideal for extinguishing liquid fuels and electrical fires.
    4. The CO2 fire extinguisher manufacturer designs the extinguisher in such a ways that it rapidly decrease oxygen levels around the fire, choking it (smothering impact).
    5. It features a massive, cone-shaped, black horn designed to operate the gas and handle cold temperatures.
    6. These cylinders, manufactured by a top manufacturer of CO2 type fire extinguishers, do not have a pressure gauge, as it is entirely dependent on the temperature. Instead, they are restricted by weight.
    7. The CO2 fire extinguisher supplier constructed this extinguisher with high-strength steel (carbon or manganese) to withstand high internal pressure.

    Applicable Areas of CO2 Fire Extinguisher

    1. Server Rooms & Data Centers
    2. Electrical Intake Rooms/Substations
    3. Laboratories
    4. Office Environments
    5. Manufacturing Facilities/Plant Rooms
    6. Commercial Kitchens
    7. Printing & Duplication Areas
    8. Hospitals & Medical Facilities
    9. Construction Sites
    10. Airport Runways & Heliports

    Technical Configuration of CO2 Fire Extinguisher

    Parameter Typical Specification
    Extinguishing Agent Carbon Dioxide (CO2)
    Type Stored pressure / Cartridge operated (common: stored pressure)
    Cylinder Material Seamless steel / Aluminum alloy
    Capacity (CO2 Charge) 2 kg, 4.5 kg, 6.8 kg, 9 kg (common sizes)
    Total Weight (Filled) 6–16 kg (depends on capacity)
    Working Pressure 55 bar (at 20°C)
    Test Pressure (Hydrostatic) 250 bar (varies by standard)
    Discharge Time 8–25 seconds (depends on size)
    Discharge Range 1.5 to 4 meters
    Operating Temperature Range -20°C to +60°C (typical)
    Nozzle Type Horn nozzle (insulated discharge horn)
    Valve Type Brass / Alloy valve with safety burst disc
    Safety Device Burst disc / Pressure relief device
    Fire Class Rating Class B (flammable liquids), Class C (electrical equipment)
    Dielectric Suitability Safe for energized electrical equipment (non-conductive agent)
    Mounting Wall bracket/vehicle bracket
    Standard Compliance (examples) EN3, IS 15683, NFPA 10 (depending on country)
    Maintenance Requirement Periodic inspection + hydro test every 5 years (typical)

    How to Properly Use a CO2 Fire Extinguisher?

    Use a CO2 fire extinguisher designed by the leading manufacturer of CO2 type fire extinguishers, only if the fire is small, there is a safe escape route, and it is the correct type for the fire. Follow these steps:

    1. Pull: Now, point the nozzle outward and pull the safety pin. The seal will break, and the lever will be unlocked.
    2. Aim: Next, point the lever downward, at the base of the fire (fuel source), not at the flames. Start from a safe distance of 6-8 feet and move closer as the fire dies down.
    3. Squeeze: Press the handle firmly. A fine mist will be generated to cool the fire, reduce oxygen, and eventually help reignite it.
    4. Sweep: Now, move the nozzle from side to side, right at the bottom of the fire, until the flames are fully extinguished. However, continue monitoring for re-ignition and repeat the process if necessary. Likewise, use the entire extinguisher to cool the area.

    CO2 fire extinguishers manufactured by a manufacturer of CO2 type fire extinguishers will empty in less than 10 seconds. You have to be quick. Once the extinguisher has been used, ventilate the area as soon as possible because CO2 can displace oxygen in an enclosed space.

    Safety Precautions to Consider for CO2 Fire Extinguisher

    CO2 fire extinguishers manufactured by a manufacturer of CO2 type fire extinguishers are highly effective for electrical fires and Class B (flammable liquid), but they need particular safety precautions due to their pressurized nature and extremely cold gas. Furthermore, here are safety precautions that you must consider when buying CO2 fire extinguishers from a leading CO2 fire extinguisher supplier:

    1. CO2 gas becomes excessively cold (-78°) during discharge, forming solid carbon dioxide (dry ice). Touching the discharge horn with bare hands can cause extreme, instant frostbite. Therefore, always hold the fire extinguisher by the handle or, if it has a specially insulated grip, by that grip.
    2. CO2 works by displacing oxygen. In small, confined, or unventilated spaces, this can rapidly create an asphyxiation hazard, as CO2 concentration can reach dangerous levels.
    3. If a CO2 extinguisher is used indoors, make sure the entire area is properly ventilated instantly afterward to remove the gas and allow oxygen levels to return to normal.
    4. Ensure to maintain a safe distance of at least 1.5 to 2 meters (approximately 5 to 6 feet) from the fire. CO2 is a gas, and standing too close can cause the pressurized discharge to disperse flaming liquid, spreading the fire instead of extinguishing it.
    5. CO2 is meant for burning liquids and electrical hazards (Class B, Class C/ Electrical, or Class E). Furthermore, it is ineffective on Class A fires (cloth, wood, and paper) because it does not cool the material sufficiently. Thus, it leads to easy reignition.
    6. When it comes to CO2 extinguishers manufactured by the best manufacturer of CO2 type fire extinguishers, wind instantly disperses the CO2 gas before it can stop the fire. It makes the extinguisher ineffective.
    7. Ensure to consider reignition because CO2 leaves no residue. It provides no security shield against reignition. Once the gas dissipates, if the field is still piping hot, the firemight start again.

    Maintenance Tips for CO2 Fire Extinguisher

    It is very important to maintain a CO2 (carbon dioxide) fire extinguisher in order to ensure that it is functioning well in the event of an electrical fire or a fire involving a flammable liquid. CO2 fire extinguishers do not have a pressure gauge, just like dry chemical fire extinguishers. Therefore, specific steps must be followed when maintaining CO2 fire extinguishers. Here are vital fire extinguisher maintenance tips:

    1. It happens because CO2 fire extinguishers lack a pressure gauge. Furthermore, the only way to verify a full charge is to weigh them annually. You will need to compare the weight with the “full weight” marked on the fire extinguisher or on the label.
    2. Inspect the fire extinguisher container monthly for visible damage, such as dents, rust, or corrosion. Also, ensure the fire extinguisher is clean, easily visible, and not obstructed by equipment or furniture.
    3. Ensure the safety pin is securely attached and the plastic anti-tamper seal is intact. If the seal is broken, the fire extinguisher has likely been used or partially discharged.
    4. When it comes to a CO2 extinguisher manufactured by a manufacturer of CO2 type fire extinguishers, ensure to check the discharge horn and hose for any signs of damage, such as cracks and blockages. In addition, verify that the horn is securely attached and not damaged by exposure to the elements (e.g., UV degradation).
    5. Ensure to schedule a professional servicing of the extinguisher annually, which includes an internal inspection and verification of the cylinder’s integrity.

    Why Choose Fire Extinguishers India to Purchase CO2 Fire Extinguishers?

    CO2 fire extinguishers are essential in every office, server room, laboratory, and commercial setting today. They are highly effective at rapidly controlling electrical and flammable liquid fires, leaving no messy residue. Hence, if you are looking for a clean, fast, and effective fire safety solution, a CO2 fire extinguisher is a wise decision.

    Buying from Fire Extinguishers India is an excellent choice because we deliver advanced quality fire extinguishers. Our team will also assist you in selecting the appropriate capacity, including placement planning and compliance support, so your system is fully protected.

    Why should you consider us?

    • Authentic, certified CO2 fire extinguishers with proper testing
    • A variety of sizes available for different industry requirements
    • Professional assistance for choosing the right extinguisher type
    • Competitive pricing with value-oriented suggestions
    • Fast delivery and quality customer service
    • Applicable for offices, server rooms, factories, and laboratories
    • Clean agent performance: no damage to equipment
    • Primary emphasis on safety standards and compliance

    Frequently Asked Questions

    No! The largest benefit of a CO2 extinguisher is that it doesn’t leave any powder or residue. Thus, it is ideal for computers, servers, lab equipment, and electronics.

    When a CO2 extinguisher is discharged, the gas becomes very cold (-78°C) and even forms dry ice. Thus, a CO2 extinguisher features a black, insulated horn that withstands cold.

    Generally, a CO2 extinguisher takes 8-25 seconds to drain (depending on its size). Therefore, prompt action is required when using a CO2 extinguisher.

    Technically, you can try it, but it’s not recommended. CO2 extinguishers do not fully extinguish Class A fires (wood, cloth, paper), so the risk of re-ignition is high.