Modular Automatic Fire Extinguishers

Modular Automatic Fire Extinguishers

Modular Automatic Fire Extinguishers

Product Overview

  • Price:
  • Type: Automatic Fire Extinguisher
Enquire Now

    Enquire About This Product

    Product Description:

    A modular automatic fire extinguisher is fully self-contained and ceiling-suspended, intended for automatic, unattended fire protection 24/7, making them suitable for high-risk, unattended areas such as server rooms or electrical panels. Furthermore, they function through a quartzoid bulb (usually 68°C) that shatters upon sensing heat, releasing ABC powder or clean agents.

    Additional Details:

    • Brand: Somya Pyrotek Services Pvt. Ltd.
    • Model: Modular Automatic Fire Extinguisher
    • Capacity: 2 kg – 12 kg
    • Maximum Coverage Area: 2 m² – 15 m² per unit
    • Temperature Range: −10°C to +55°C
    • Working Pressure: 12 to 25 bar
    • Rechargeability: Refillable
    • Cylinder Material: Mild Steel / Aluminum
    • Agent Release Time: 5 to 10 seconds

    Key Features of Modular Automatic Fire Extinguishers

    Explore the key features of a modular automatic fire extinguisher before purchasing it to safeguard your spaces from fire:

    • It consists of premium-quality MAP 90% powder.
    • It has an exceptional gauge testing system mechanism.
    • It is designed with a solid interior and exterior with pure polyester powder.
    • A modular automatic fire extinguisher operates independently, detecting fires and discharging extinguishing agents quickly without human intervention.
    • An automatic dry powder fire extinguisher is normally available in 2kg, 5kg, 10kg, and 15kg capacities to prevent multiple hazard sizes.
    • It is easy to maintain, recharge, and service, as well as it is more economical than others.
    • A modular automatic fire extinguisher provides protection in emergencies and during power outages without a power backup.

    Applicable Areas of Modular Automatic Fire Extinguishers

    • Fuel and Flammable Liquid Storage
    • Oil Fill-in Station
    • Paint and Varnish Rooms
    • Bus and Car Engines
    • Hotels, Restaurants, Motels
    • Telecom Shelter and Tower
    • Electrical Panels
    • Train: Electric Distributor Coach
    • Fuel and Flammable Liquid Storage
    • Computer Area
    • ATM Center
    • Server Rooms
    • Domestic Gas Storages

    Technical Configuration

    Category Parameter Specification
    General System Type Modular Automatic Fire Extinguisher
    General Activation Mode Automatic / Manual
    Extinguishing Agent Agent Type Clean Agent / ABC Powder / CO₂ / FM-200 / Novec 1230
    Capacity Cylinder Size 2 kg – 12 kg
    Coverage Area Maximum Coverage 2 m² – 15 m² per unit
    Discharge Time Agent Release Time 5–10 seconds
    Operating Temperature Temperature Range −10°C to +55°C
    Operating Pressure Working Pressure 12–25 bar
    Detection System Trigger Mechanism Thermal Bulb / Fusible Link
    Nozzle Type Discharge Nozzle Cone / Multi-spray
    Mounting Installation Type Wall-Mounted / Ceiling-Mounted
    Material Cylinder Material Mild Steel / Aluminum
    Safety Pressure Relief Valve Included
    Monitoring Pressure Gauge Analog / Digital
    Electrical Power Requirement None (Self-contained)
    Reset Rechargeability Refillable
    Maintenance Inspection Interval 6–12 months
    Certification Safety Certification UL / CE / BIS / NFPA
    Application Suitable Areas Server Rooms, Panels, Vehicles, Cabinets
    Warranty Warranty Period 1–5 Years

    How to Use Modular Automatic Fire Extinguishers?

    Here, we have outlined four easy steps to remember for operating a modular automatic fire extinguisher. Let’s discuss the PASS extinguisher system together:

    • Pull the pin while holding the fire extinguisher at a distance from you to unlock the nozzle.
    • Aim low towards the bottom of the fire.
    • Squeeze the nozzle slowly and steadily towards the fire base.
    • Sweep the extinguisher’s nozzle from side to side at the bottom of the fire.

    It is beneficial to know how to use the automatic dry powder fire extinguisher, but it is not the end of training. Furthermore, extinguisher users should be well-trained to stick to the following protocol:

    • If necessary, sound the fire alarm or call the fire department.
    • Before going to the fire, find an escape route that avoids flames, intense heat, and smoke. Do not let this escape route become obstructed.
    • Follow the PASS method to operate the extinguisher and move away from the area if the fire increases.
    • If the fire extinguisher is empty and the fire is not extinguished properly, clear the area immediately.
    • If the fire becomes too large to control, evacuate the area immediately.

    Maintenance Tips for Modular Automatic Fire Extinguishers

    Here is the monthly maintenance and inspection checklist of the modular automatic fire extinguisher:

    • One of the vital factors that every individual should consider is to check the pressure of the extinguisher regularly. Furthermore, ensure the pressure gauge needle is in the green zone.
    • It is crucial to have a visual inspection weekly. While doing so, make sure you check for any physical damage, such as rust, corrosion, or dents, especially since these are mounted in hard-to-reach places.
    • Ensure to confirm that the safety seal is intact and the pin is in place.
    • While inspecting, ensure that the discharge nozzle and thermal bulb or fuse of the automatic dry powder fire extinguisher are free of obstructions, dust, or grease.
    • It is crucial to verify that the fire extinguisher is not blocked by stored materials. Likewise, make sure it provides proper heat detection and coverage.
    • Ensure that the date and initials are intact on the extinguisher to log the monthly inspection.

    Why Choose Us?

    Fire safety should be a non-compromising option, and that’s why Fire Extinguishers India is your trusted choice. We design advanced modular automatic fire extinguisher systems that detect and suppress fires instantly, with no manual intervention. Moreover, our aim is always to be reliable, innovative, and customer-focused, ensuring you get a powerful, maintenance-friendly fire protection solution. Likewise, here are some vital and competitive reasons why you should choose us for purchasing a modular automatic fire extinguisher:

    • Our fire extinguishers are manufactured with advanced automatic fire suppression technologies.
    • We offer high-quality, certified, and durable products.
    • Our fire extinguishers consist of low-maintenance systems, and they are easy to install in the preferred area.
    • We offer customized solutions for every industry.
    • We provide reliable after-sales support & expert guidance.

    Frequently Asked Questions

    An automatic dry powder fire extinguisher is useful in multiple areas, such as:

    1. Unoccupied spaces or rooms
    2. Server room and safety protection in large storage areas.

    Furthermore, it is exceptional for round-the-clock protection for hidden areas. Additionally, it does not require cumbersome piping and is easy to install.

    A modular automatic fire extinguisher is an automatic device that activates and discharges its contents when it senses high heat from a fire. Unlike conventional fire extinguishers that require human operation, these fire extinguishers function independently.

    An automatic dry powder fire extinguisher is very impactful, beneficial, and effective, especially in inaccessible and closed areas where fire could cause serious damage if not extinguished or detected in time. Furthermore, the temperature range is 57°C to 107°C to detect fire in such places.

    The primary function of a modular automatic fire extinguisher is to respond rapidly when a fire occurs and to alert building occupants and emergency action personnel before extensive damage occurs. Additionally, an automatic fire detection system uses electronic sensors to detect heat, smoke, or flames and provide an early warning.

    When it comes to the golden rule of an automatic dry powder fire extinguisher, it is imperative to only try to extinguish a fire if it is small and contained, and you have a clear way to the exit. Thus, never put yourself or others in a dangerous situation while trying to control a fire that is expanding, spreading rapidly, or producing heavy smoke.